Centrifugal fan for the potash industry – 39,000 m³/h at 5,200 Pa, 90 kW IE4 via intermediate shaft and coupling
Salt, pressure, sensors? We can do that.
In the potash industry, salt is everywhere – and salt is the natural enemy of steel. For the exhaust air treatment of its plant, a customer of ZENNER Ventilatoren Werke GmbH needed a reliable, powerful fan and, as in earlier projects, came to us with its specifications. The result is a coupling-driven centrifugal fan designed for exactly this duty point.
The task in figures: at a medium temperature of 60 °C, the 1,250 mm impeller conveys a volume flow of 39,000 m³/h against a total pressure difference of 5,200 Pa. For an exhaust air system that is a high figure – every cleaning stage and every metre of ducting costs pressure, and the fan has to make up for that loss day after day.
The impeller is driven by a four-pole IE4 motor rated at 90 kW – not directly, but via an intermediate shaft and coupling. In this coupling-driven design, the motor sits on its own pedestal outside the air stream; the intermediate shaft with its bearings takes up the forces of the impeller, and the motor stays clear of the medium and its heat. For high drive powers and large impeller diameters, this is the design of choice.
At the customer's request, a speed sensor and two bearing temperature sensors were fitted to the intermediate shaft. Speed and bearing temperature are the values that give a fan away earliest in operation: if the bearing temperature rises, something is wrong with lubrication, load or alignment – long before anyone hears it. This way the fan can be integrated into the plant's condition monitoring.
The housing received an inspection opening and a condensate connection. The connection is there in case moisture from the warm exhaust air condenses on the housing walls – and where salt is involved, nothing should be left standing inside the housing. The inspection opening allows a look at the impeller without taking the fan out of the ductwork.
Integration into the plant is ensured by the equipment:
- intermediate shaft with coupling, motor on its own pedestal
- speed sensor and two bearing temperature sensors on the intermediate shaft
- inspection opening and condensate connection on the housing
- compensators on the suction and pressure sides
- vibration dampers to isolate the unit from the foundation
- separate splitter silencer on the pressure side, 1,500 × 1,500 mm, 1,250 mm high
With all accessories, the fan unit measures 2,300 mm in width, 2,300 mm in height and 2,800 mm in length and weighs 2,600 kg. The splitter silencer comes separately and takes the noise that 90 kW inevitably produce out of the pressure side.
All paintable parts carry a C5 coating with "high" durability in RAL 5015 (sky blue). C5 is the highest corrosivity category under ISO 12944 – intended for salt spray, chemicals and permanently high humidity. Exactly the environment in which a fan in the potash industry spends its working life.
Sky blue looks friendly. Underneath is the toughest corrosion protection the standard knows – performance for the most diverse customers, made in Germany.
Another example of the fact that a fan is not just a fan.
ZENNER Ventilatoren – Durable. Low-maintenance. Quality since 1947.
Made in Germany.
This version is suitable when:
- an exhaust air treatment system has high pressure losses – here 5,200 Pa at 39,000 m³/h
- the environment is highly corrosive, for instance due to salt, chemicals or permanently high humidity (corrosivity category C5)
- high drive powers and large impellers are required and the motor is to sit outside the air stream (coupling drive)
- the operator wants to monitor speed and bearing temperature and integrate the fan into the plant control system
- condensate can form inside the housing and has to be drained
- noise emission on the pressure side has to be limited
It is not suitable when:
- only small volume flows or low pressures are needed – a compact, directly driven fan is then the more economical choice
- installation space or weight is tightly limited – the unit measures 2.3 × 2.3 × 2.8 m and weighs 2.6 t
- an ATEX zone applies inside the fan – that calls for an explosion-proof version
- medium temperatures far above 60 °C occur, as covered by a hot-gas fan
- highly abrasive solids are conveyed that require a wear-protected version
- Application: exhaust air treatment in the potash industry
- Medium temperature: 60 °C
- Design: centrifugal fan, coupling drive (intermediate shaft and coupling)
- Volume flow: 39,000 m³/h
- Total pressure difference: 5,200 Pa
- Impeller: 1,250 mm, designed for the duty point
- Drive: four-pole IE4 motor, 90 kW
- Sensors: speed sensor and two bearing temperature sensors on the intermediate shaft
- Housing: inspection opening, condensate connection
- Accessories: compensators on suction and pressure sides, vibration dampers
- Silencer: splitter silencer on the pressure side, 1,500 × 1,500 mm, 1,250 mm high, separate
- Corrosion protection: C5 coating, high durability, RAL 5015 sky blue
- Dimensions: 2,300 mm (W) × 2,300 mm (H) × 2,800 mm (L), weight 2,600 kg
- Manufacturing: made to order in Germany